Although we at Newark Copper Cylinder have been manufacturing Thermalstore Cylinders for decades, we focused our efforts on producing bespoke themalstores for unique settings.

As a contrast to that, we have decided to produce a range of all-in-one thermalstore cylinders with a ready-defined specification suitable for a multitude of heat sources.

Wood Burner

Gas/Oil Boiler

Solar

Underfloor Heating

Specification

The 22mm Vent Connection on a thermalstore connects to the feed an expansion tank to allow the water in the system to expand once the tank reaches temperature.

250L 300L 400L 450L 500L
1775mm TBC TBC TBC TBC

The 22mm Boiler Directs are connected to a conventional oil / gas boiler which allows water to be heated and circulated back into the tank.

250L 300L 400L 450L 500L
1490mm TBC TBC TBC TBC

The 1/2" Dial Gauge is used to display the internal temperature of the tank.

250L 300L 400L 450L 500L
1180mm TBC TBC TBC TBC

The 28mm Wood Burner Connections are connected to a wood burner with a back boiler to utilse heat provided by the wood burner to also provide heating to the water tank.

250L 300L 400L 450L 500L
1040mm TBC TBC TBC TBC

A 3Kw Immersion heater is used to top up heat in the unit using an electrical heating element.

250L 300L 400L 450L 500L
630mm TBC TBC TBC TBC

A 22mm Solar coil is used to provide heat to the tank utilising solar panels situated on the roof of the property which heats water circulated through the coil.

250L 300L 400L 450L 500L
570mm TBC TBC TBC TBC

A 22mm Solar coil is used to provide heat to the tank utilising solar panels situated on the roof of the property which heats water circulated through the coil.

250L 300L 400L 450L 500L
270mm TBC TBC TBC TBC

The 28mm Wood Burner Connections are connected to a wood burner with a back boiler to utilse heat provided by the wood burner to also provide heating to the water tank.

250L 300L 400L 450L 500L
170mm TBC TBC TBC TBC

The 22mm Boiler Directs are connected to a conventional oil / gas boiler which allows water to be heated and circulated back into the tank.

250L 300L 400L 450L 500L
270mm TBC TBC TBC TBC

The Thermalstore utilised a high surface area finned coil which is used to exchange heat between the coil and the tank which is used to draw off hot water through a thermal mixer valve fitted to the external pipework.

250L 300L 400L 450L 500L
1515mm TBC TBC TBC TBC

The Temperature & Pressure Relief Valve is fitted when an uncontrolled heat source is utilised, this ensures that the tank does not overpressurise or get too high temperature by opening the valve to dump any excess heat or pressure.

250L 300L 400L 450L 500L
1490mm TBC TBC TBC TBC

The Thermal Mixer Valve is used to control the output temperature of the tank with the mix of hot water provided by the tank and the incoming cold mains. It can be adjusted to output heat between 30°C - 70°C at 25Lpm.

Heat is provided to the underfloor heating system by utilising a high-efficiency Plate Heat Exchanger. It is done to separate the body of water within the tank with the water in the underfloor heating circuit as thin pipe is often used for underfloor heating and can be very difficult to replace if any contaminates in the tank was to cause a blockage.

250L 300L 400L 450L 500L
1490mm TBC TBC TBC TBC

An expansion vessel is fitted on the external pipework in order to facilitate any excess expansion in system.

The Thermalstore utilised a high surface area finned coil which is used to exchange heat between the coil and the tank which is used to draw off hot water through a thermal mixer valve fitted to the external pipework.

250L 300L 400L 450L 500L
715mm TBC TBC TBC TBC

Heat is provided to the underfloor heating system by utilising a high-efficiency Plate Heat Exchanger. It is done to separate the body of water within the tank with the water in the underfloor heating circuit as thin pipe is often used for underfloor heating and can be very difficult to replace if any contaminates in the tank was to cause a blockage.

250L 300L 400L 450L 500L
170mm TBC TBC TBC TBC

The Radiator circuit is connected to a circulating pump and zone valve in order to circulate water in the body of the thermalstore through the radiator circuit in the premesis.

250L 300L 400L 450L 500L
890mm TBC TBC TBC TBC

A Thermostat Pocket is used to determine the temperature at a particular point in the tank, this is usually connected to a system for controlling or monitoring the temperature of the input or output at that height.

250L 300L 400L 450L 500L
1210mm TBC TBC TBC TBC

A Thermostat Pocket is used to determine the temperature at a particular point in the tank, this is usually connected to a system for controlling or monitoring the temperature of the input or output at that height.

250L 300L 400L 450L 500L
780mm TBC TBC TBC TBC

A Thermostat Pocket is used to determine the temperature at a particular point in the tank, this is usually connected to a system for controlling or monitoring the temperature of the input or output at that height.

250L 300L 400L 450L 500L
430mm TBC TBC TBC TBC

A Thermostat Pocket is used to determine the temperature at a particular point in the tank, this is usually connected to a system for controlling or monitoring the temperature of the input or output at that height.

250L 300L 400L 450L 500L
430mm TBC TBC TBC TBC

A 3Kw Immersion heater is used to top up heat in the unit using an electrical heating element.

250L 300L 400L 450L 500L
210mm TBC TBC TBC TBC

The Radiator circuit is connected to a circulating pump and zone valve in order to circulate water in the body of the thermalstore through the radiator circuit in the premesis.

250L 300L 400L 450L 500L
170mm TBC TBC TBC TBC

A drain valve is used to drain water from the body of water in the tank and is usually utilsed for maintenance.

250L 300L 400L 450L 500L
170mm TBC TBC TBC TBC