Newark Copper Cylinder Co Ltd

Combination Cylinders

Combination Cylinders

As the name suggests the combination cylinder (or tank) combines both hot and cold water cisterns in an integrated package.

Ideally suited for multi-storey developments, where space is limited or where the installation of the header tank is proving difficult. Combination cylinders are available in direct, indirect or single feed patterns.

All combination cylinders are manufactured to meet the specifications of the British Standard B.S. 3198, and the following range carry the kitemark symbol:

HeightsDiameterCapacity (Litres)
  HotCold
900mm450mm8525
1050mm450mm11425
1200mm*450mm11445
1300mm450mm13045
1400mm*450mm14445
1850mm*450mm21045

*available to Economy 7 specification.

Each unit can come complete with Byelaw kit, ball valve, immersion heater and drain valve allready fitted to ease installation.

Other sizes, still manufactured to meet the rigorous British Standard specification, are available in a combination of heights and diameters as detailed below:

Heights
900mm
1075mm
1200mm
1300mm
1400mm
1500mm
1850mm
Diameters
350mm
375mm
400mm
450mm
500mm

All units, unless specified otherwise, are supplied with factory applied insulation. To ease installation Byelaw kits, ball valves, immersion heaters and drain cocks can also be factory fitted. Other options are available to meet customers' particular needs including Economy 7 specification, split header tanks to support the central heating system's feed and expansion, and additional tappings (e.g. for shower fittings).

Cylinder Dimensions

Combination Cylinders dimensions diagram
Letter on DiagramConnection type
A1" Male
B1" male
C3/4" female
D1/2" female
E2.1/4" Female

Back to Top

WAI-AA | XHTML | CSS | Terms | Privacy | © Newark Copper Cylinders Co Ltd 1977 - 2008